Absorbency and barrier pull in opposite directions. A gown needs one; a dressing needs the other.
— %
Fluid held as a percentage of dry weight
Hydrostatic head per unit weight divides the head by the basis weight, to compare fabrics of different weight. It is not the Barrier Index of EN 13795-1, which is the result of the wet bacterial penetration test, EN ISO 22610. AAMI barrier levels are defined by hydrostatic head and impact penetration together. A single hydrohead figure does not classify a gown on its own. Strike-through time is a different test on a different specimen and is not used here.
Medical Nonwoven Absorbency & Barrier Calculator — free, with the formula and a worked example, at Textile School.