Machine Maintenance

Stenter Chain Lubrication Consumption vs Oven Temperature

Under-dose and the chain seizes in the rail. Over-dose and it drips on the cloth. Past a certain oven temperature, no dose avoids both.

Lubrication System Dosing
mL/h

Requirement at the reference oven temperature.

no.
mL/h

Total dose above which oil reaches the fabric.

Oven & Line Running
°C
°C
×
m
m/min
h

Required Oil Dose

— mL/h

Total dose needed to replace what the oven takes

Dosing & Limits

Consumption Acceleration
— ×
Margin to Dripping
— mL/h
Highest Non-Dripping Temperature
— °C
Oil per Shift
— L
Chain Circuit Time
— min

A negative drip margin does not mean the chain will be starved — it means the dose required to keep it lubricated is itself high enough to contaminate the fabric, and the answer is a higher-temperature oil or a different lubrication strategy rather than a different dose. Both the Q10 factor and the drip threshold are plant-specific and must be established from oil consumption logs and staining incidents on the actual machine; a synthetic high-temperature chain oil has a quite different Q10 from a mineral one. The chain also sees its highest temperature in the hottest zone rather than the average, and it is that zone which governs.

Stenter Chain Lubrication Consumption vs Oven Temperature — free, with the formula and a worked example, at Textile School.