Home » Calculators » Mill Operations & Industrial Engineering » Factory Physics & Assembly Logistics » Seamless Garment Heat-Setting Shrinkage Modeler
Jump to a calculator 618 tools

Seamless Knitting

Seamless Garment Heat-Setting Shrinkage Modeler

Put this calculator on your own site

Paste this where you want the calculator to appear. It works on any site — WordPress, Squarespace, Webflow, Ghost or plain HTML — and needs no JavaScript of yours. It carries a link back here, which is the only thing we ask for it.

See what it looks like

Boarding temperature moves shrinkage far more than dwell does. Knit the greige for the oven you actually run.

Boarding Oven setting
°C
s
Calibration Reference run
°C
%
%/°C
s
Garment Dimensions
cm
cm

Boarding Shrinkage

— %

At the working temperature and dwell

Dimensional Result

Shrinkage from Temperature Alone
— %
Dwell Multiplier
— ×
Finished Length
— cm
Length Lost
— cm
Greige Length for Target
— cm
Greige Change Needed
— cm

Fitted coefficients, valid only across the temperature band they were measured in — past the elastane's setting window shrinkage stops rising and the fibre degrades instead. Boarding also sets width and recovery, which this does not model; check both on the boarded garment.

Using this calculator

About the Seamless Garment Heat-Setting Shrinkage Modeler

The formula

This is the expression the tool evaluates. Every term is named underneath, with the unit it must be supplied in.

Boarding Shrinkage
totalShrinkage = f( boardingTemp, dwellTime, referenceTemp, referenceShrinkage, tempCoefficient, referenceDwell, dwellExponent, greigeLength, targetLength )

Each input feeds the expression evaluated in the browser; the symbol table below names every term and its unit.

Symbols used above
SymbolStands forUnit
boardingTempBoarding Temperature°C
dwellTimeDwell Times
referenceTempReference Temperature°C
referenceShrinkageShrinkage at Reference%
tempCoefficientShrinkage per °C%/°C
referenceDwellReference Dwells
dwellExponentDwell Exponent—
greigeLengthGreige Lengthcm
targetLengthTarget Finished Lengthcm
totalShrinkageBoarding Shrinkage%
tempShrinkageShrinkage from Temperature Alone%
dwellFactorDwell Multiplier×
finishedLengthFinished Lengthcm
shrinkageCmLength Lostcm
greigeForTargetGreige Length for Targetcm
greigeAdjustmentGreige Change Neededcm

How the result is derived

Step by step, from the values you type to the figure on screen.

  1. The 9 inputs are read from the form on every keystroke: Boarding Temperature, Dwell Time, Reference Temperature, Shrinkage at Reference, Shrinkage per °C, Reference Dwell, Dwell Exponent, Greige Length and Target Finished Length.
  2. Each value is checked against the accepted range in the input table below. A value outside its range stops the calculation rather than producing a misleading figure — the results blank out and a message appears.
  3. The validated values are substituted into the expression above, which resolves Boarding Shrinkage together with every supporting figure in one pass — no value is carried over from a previous entry.
  4. The supporting outputs — Shrinkage from Temperature Alone, Dwell Multiplier, Finished Length, Length Lost, Greige Length for Target and Greige Change Needed — come from the same pass, so they always describe the same case as the headline figure.
  5. Results are rounded for display only. The full-precision value is used throughout the chain, so reading a rounded intermediate figure back into the tool by hand can shift the last digit.

What each input means

Where to read each value on the floor, the unit it must be in, and the range the tool accepts.

InputUnitAccepted rangeDefaultWhat it means
Boarding Temperature°C120 to 230 °C195
Dwell Times5 to 300 s45
Reference Temperature°C120 to 230 °C180
Shrinkage at Reference%0.1 to 40 %8
Shrinkage per °C%/°C0.01 to 2 %/°C0.35
Reference Dwells5 to 300 s40
Dwell Exponent—0 to 10.2
Greige Lengthcm5 to 300 cm70
Target Finished Lengthcm5 to 300 cm62

What the tool returns

The headline figure and every supporting value it is built from.

OutputUnitWhat it tells you
Boarding Shrinkage (headline result)%At the working temperature and dwell
Shrinkage from Temperature Alone%
Dwell Multiplier×
Finished Lengthcm
Length Lostcm
Greige Length for Targetcm
Greige Change Neededcm

Worked example

Given

Boarding Temperature
195 °C
Dwell Time
45 s
Reference Temperature
180 °C
Shrinkage at Reference
8 %
Shrinkage per °C
0.35 %/°C
Reference Dwell
40 s
Dwell Exponent
0.2
Greige Length
70 cm
Target Finished Length
62 cm

The tool loads with this case already solved — the Boarding Shrinkage shown above is its answer. Change one value and the difference from this baseline is the sensitivity of the result to that variable.

How to use it

  1. Work through the input groups in order — Boarding, Calibration and Garment. The defaults are a realistic case, so you can change one value at a time and watch what moves.
  2. There is no calculate button. Every figure recalculates as you type or drag, which is what makes this usable for a what-if sweep rather than a single answer.
  3. Read Boarding Shrinkage in the dark results panel — that is the headline figure, expressed in %.
  4. Check the supporting rows underneath (Shrinkage from Temperature Alone, Dwell Multiplier, Finished Length, Length Lost, Greige Length for Target and Greige Change Needed) before acting on the headline — they are where an implausible input usually shows itself first.
  5. Reset to defaults returns every field to the reference case, which is the quickest way to check whether a surprising result came from the tool or from an input you had changed earlier.

Where this is used

  • Process planning — establishing Boarding Shrinkage before a trial is booked, so machine time and material in Factory Physics & Assembly Logistics are committed against a calculated figure rather than an estimate.
  • Costing and quotation — Boarding Shrinkage is an input to the cost sheet, and quoting from a worked number rather than a remembered one is what keeps a margin intact.
  • Troubleshooting — when the floor result drifts from plan, entering the measured values (starting with Boarding Temperature) shows how much of the gap in Boarding Shrinkage each variable explains.
  • Teaching and study — the accepted ranges bracket normal Factory Physics & Assembly Logistics practice, so moving one variable at a time shows the shape of the relationship rather than a single answer.

Assumptions and limits

  • Fitted coefficients, valid only across the temperature band they were measured in — past the elastane's setting window shrinkage stops rising and the fibre degrades instead. Boarding also sets width and recovery, which this does not model; check both on the boarded garment.
  • Every input is bounded to the range normal practice occupies (Boarding Temperature 120 to 230 °C, Dwell Time 5 to 300 s and Reference Temperature 120 to 230 °C, and so on for the rest). Those bounds are guard rails against typing errors, not a claim that the formula fails one unit outside them.
  • The calculation is deterministic: the same inputs always give the same result. It carries no allowance for machine condition, operator skill, ambient conditions or lot-to-lot material variation unless an input above explicitly represents one.
  • Nothing is sent anywhere. The maths runs in your browser, so the numbers you type never leave the page.

Questions people ask

What do I need to know before using the Seamless Garment Heat-Setting Shrinkage Modeler?

Have these to hand: Boarding Temperature, Dwell Time, Reference Temperature, Shrinkage at Reference, Shrinkage per °C, Reference Dwell, Dwell Exponent, Greige Length and Target Finished Length. With those entered, the tool returns Boarding Shrinkage immediately.

What exactly is Boarding Shrinkage?

At the working temperature and dwell. It is reported in %. It is derived from Boarding Temperature, Dwell Time, Reference Temperature, Shrinkage at Reference, Shrinkage per °C, Reference Dwell, Dwell Exponent, Greige Length and Target Finished Length, and is the figure the rest of the Factory Physics & Assembly Logistics calculation is built around.

Which units does this calculator expect?

Enter Boarding Temperature in °C, Dwell Time in s, Reference Temperature in °C, Shrinkage at Reference in %, Shrinkage per °C in %/°C, Reference Dwell in s, Greige Length in cm and Target Finished Length in cm. Mixing unit systems is the most common cause of a result that looks an order of magnitude wrong — convert before typing, not after reading.

What are the other figures under the main result?

They are the intermediate quantities the calculation passes through: Shrinkage from Temperature Alone, Dwell Multiplier, Finished Length, Length Lost, Greige Length for Target and Greige Change Needed. They are shown because a headline number nobody can trace is a number nobody trusts — checking them against your own expectation is the fastest way to confirm the inputs were read as you intended.

Can I rely on this for a production decision?

Fitted coefficients, valid only across the temperature band they were measured in — past the elastane's setting window shrinkage stops rising and the fibre degrades instead. Boarding also sets width and recovery, which this does not model; check both on the boarded garment. Treat the output as an engineering estimate that narrows the trial window, not as a substitute for the trial.

Scroll to Top