Home » Calculators » Technical & Performance Textiles » Composites, Aerospace & Automotive Textiles » Woven Roving Thickness & Laminate Stack Planner
Jump to a calculator 618 tools

Composites

Woven Roving Thickness & Laminate Stack Planner

Put this calculator on your own site

Paste this where you want the calculator to appear. It works on any site — WordPress, Squarespace, Webflow, Ghost or plain HTML — and needs no JavaScript of yours. It carries a link back here, which is the only thing we ask for it.

See what it looks like

Ply thickness is not a property of the cloth — it is a property of the cloth and the volume fraction your process actually reaches.

Reinforcement Per ply
g/m²
g/cm³

E-glass 2.55, carbon 1.79, aramid 1.44.

%

Hand layup 30–40%, vacuum bag 45–55%, infusion 50–60%.

g/cm³
Laminate Target
mm

Cured Ply Thickness

— mm

At the achievable fibre volume fraction

Stack Plan

Plies Required
— no.
Thickness Delivered
— mm
Laminate Weight
— kg/m²
Resin Required
— kg/m²
Resin to Glass Ratio
— ×

Fibre volume fraction is the whole answer and it is a process property, not a material one — the same cloth hand-laid and infused differs by nearly half a ply in thickness. Resin demand here is what ends up in the laminate; add the consumables, feed lines and catch pot before ordering.

Using this calculator

About the Woven Roving Thickness & Laminate Stack Planner

The formula

This is the expression the tool evaluates. Every term is named underneath, with the unit it must be supplied in.

Cured Ply Thickness
plyThickness = f( fabricGsm, fibreDensity, targetFvf, resinDensity, targetThickness )

Each input feeds the expression evaluated in the browser; the symbol table below names every term and its unit.

Symbols used above
SymbolStands forUnit
fabricGsmFabric Areal Weightg/m²
fibreDensityFibre Densityg/cm³
targetFvfAchievable Fibre Volume Fraction%
resinDensityResin Densityg/cm³
targetThicknessTarget Laminate Thicknessmm
plyThicknessCured Ply Thicknessmm
pliesRequiredPlies Requiredno.
actualThicknessThickness Deliveredmm
laminateArealWeightLaminate Weightkg/m²
resinDemandResin Requiredkg/m²
resinToGlassRatioResin to Glass Ratio×

How the result is derived

Step by step, from the values you type to the figure on screen.

  1. The 5 inputs are read from the form on every keystroke: Fabric Areal Weight, Fibre Density, Achievable Fibre Volume Fraction, Resin Density and Target Laminate Thickness.
  2. Each value is checked against the accepted range in the input table below. A value outside its range stops the calculation rather than producing a misleading figure — the results blank out and a message appears.
  3. The validated values are substituted into the expression above, which resolves Cured Ply Thickness together with every supporting figure in one pass — no value is carried over from a previous entry.
  4. The supporting outputs — Plies Required, Thickness Delivered, Laminate Weight, Resin Required and Resin to Glass Ratio — come from the same pass, so they always describe the same case as the headline figure.
  5. Results are rounded for display only. The full-precision value is used throughout the chain, so reading a rounded intermediate figure back into the tool by hand can shift the last digit.

What each input means

Where to read each value on the floor, the unit it must be in, and the range the tool accepts.

InputUnitAccepted rangeDefaultWhat it means
Fabric Areal Weightg/m²50 to 5000 g/m²800
Fibre Densityg/cm³1 to 3.5 g/cm³2.55E-glass 2.55, carbon 1.79, aramid 1.44.
Achievable Fibre Volume Fraction%15 to 75 %45Hand layup 30–40%, vacuum bag 45–55%, infusion 50–60%.
Resin Densityg/cm³0.8 to 2 g/cm³1.2
Target Laminate Thicknessmm0.2 to 200 mm12

What the tool returns

The headline figure and every supporting value it is built from.

OutputUnitWhat it tells you
Cured Ply Thickness (headline result)mmAt the achievable fibre volume fraction
Plies Requiredno.
Thickness Deliveredmm
Laminate Weightkg/m²
Resin Requiredkg/m²
Resin to Glass Ratio×

Worked example

Given

Fabric Areal Weight
800 g/m²
Fibre Density
2.55 g/cm³
Achievable Fibre Volume Fraction
45 %
Resin Density
1.2 g/cm³
Target Laminate Thickness
12 mm

The tool loads with this case already solved — the Cured Ply Thickness shown above is its answer. Change one value and the difference from this baseline is the sensitivity of the result to that variable.

How to use it

  1. Work through the input groups in order — Reinforcement and Laminate. The defaults are a realistic case, so you can change one value at a time and watch what moves.
  2. There is no calculate button. Every figure recalculates as you type or drag, which is what makes this usable for a what-if sweep rather than a single answer.
  3. Read Cured Ply Thickness in the dark results panel — that is the headline figure, expressed in mm.
  4. Check the supporting rows underneath (Plies Required, Thickness Delivered, Laminate Weight, Resin Required and Resin to Glass Ratio) before acting on the headline — they are where an implausible input usually shows itself first.
  5. Reset to defaults returns every field to the reference case, which is the quickest way to check whether a surprising result came from the tool or from an input you had changed earlier.

Where this is used

  • Process planning — establishing Cured Ply Thickness before a trial is booked, so machine time and material in Composites, Aerospace & Automotive Textiles are committed against a calculated figure rather than an estimate.
  • Costing and quotation — Cured Ply Thickness is an input to the cost sheet, and quoting from a worked number rather than a remembered one is what keeps a margin intact.
  • Troubleshooting — when the floor result drifts from plan, entering the measured values (starting with Fabric Areal Weight) shows how much of the gap in Cured Ply Thickness each variable explains.
  • Teaching and study — the accepted ranges bracket normal Composites, Aerospace & Automotive Textiles practice, so moving one variable at a time shows the shape of the relationship rather than a single answer.

Assumptions and limits

  • Fibre volume fraction is the whole answer and it is a process property, not a material one — the same cloth hand-laid and infused differs by nearly half a ply in thickness. Resin demand here is what ends up in the laminate; add the consumables, feed lines and catch pot before ordering.
  • Every input is bounded to the range normal practice occupies (Fabric Areal Weight 50 to 5000 g/m², Fibre Density 1 to 3.5 g/cm³ and Achievable Fibre Volume Fraction 15 to 75 %, and so on for the rest). Those bounds are guard rails against typing errors, not a claim that the formula fails one unit outside them.
  • The calculation is deterministic: the same inputs always give the same result. It carries no allowance for machine condition, operator skill, ambient conditions or lot-to-lot material variation unless an input above explicitly represents one.
  • Nothing is sent anywhere. The maths runs in your browser, so the numbers you type never leave the page.

Questions people ask

What do I need to know before using the Woven Roving Thickness & Laminate Stack Planner?

Have these to hand: Fabric Areal Weight, Fibre Density, Achievable Fibre Volume Fraction, Resin Density and Target Laminate Thickness. With those entered, the tool returns Cured Ply Thickness immediately.

What exactly is Cured Ply Thickness?

At the achievable fibre volume fraction. It is reported in mm. It is derived from Fabric Areal Weight, Fibre Density, Achievable Fibre Volume Fraction, Resin Density and Target Laminate Thickness, and is the figure the rest of the Composites, Aerospace & Automotive Textiles calculation is built around.

Which units does this calculator expect?

Enter Fabric Areal Weight in g/m², Fibre Density in g/cm³, Achievable Fibre Volume Fraction in %, Resin Density in g/cm³ and Target Laminate Thickness in mm. Mixing unit systems is the most common cause of a result that looks an order of magnitude wrong — convert before typing, not after reading.

What are the other figures under the main result?

They are the intermediate quantities the calculation passes through: Plies Required, Thickness Delivered, Laminate Weight, Resin Required and Resin to Glass Ratio. They are shown because a headline number nobody can trace is a number nobody trusts — checking them against your own expectation is the fastest way to confirm the inputs were read as you intended.

Can I rely on this for a production decision?

Fibre volume fraction is the whole answer and it is a process property, not a material one — the same cloth hand-laid and infused differs by nearly half a ply in thickness. Resin demand here is what ends up in the laminate; add the consumables, feed lines and catch pot before ordering. Treat the output as an engineering estimate that narrows the trial window, not as a substitute for the trial.

Scroll to Top