Paste this where you want the calculator to appear. It works on any site — WordPress, Squarespace, Webflow, Ghost or plain HTML — and needs no JavaScript of yours. It carries a link back here, which is the only thing we ask for it.
Report Scope 1 and 2 and you have described the boiler house. Purchased fibre is usually the larger number by some margin.
Total Footprint
—t CO₂e/yr
Scope 1, 2 and 3 combined
Footprint Breakdown
Scope 3 Total
—t CO₂e/yr
Scope 1 + 2 Total
—t CO₂e/yr
Emission Intensity
—kg CO₂e/kg
Scope 3 Share of Total
—%
Purchased Fibre Share of Total
—%
Purchased Fibre Emissions
—t CO₂e/yr
Emission factors are the whole answer and they vary enormously by fibre, origin and grid — conventional cotton, recycled polyester and virgin nylon are not within a factor of five of each other. Use factors from a recognised database with the vintage recorded, and treat this as a screening model rather than a reportable inventory.
Using this calculator
About the Total CO₂e Footprint Calculator (Scope 1, 2 & 3)
The formula
This is the expression the tool evaluates. Every term is named underneath, with the unit it must be supplied in.
Each input feeds the expression evaluated in the browser; the symbol table below names every term and its unit.
Symbols used above
Symbol
Stands for
Unit
scope1
Scope 1 — Direct Combustion
t CO₂e/yr
scope2
Scope 2 — Purchased Electricity
t CO₂e/yr
purchasedFibre
Fibre & Yarn Purchased
t/yr
fibreFactor
Fibre Emission Factor
kg CO₂e/kg
purchasedChemicals
Chemicals & Dyes Purchased
t/yr
chemicalFactor
Chemical Emission Factor
kg CO₂e/kg
freightTonneKm
Freight Activity
t·km/yr
freightFactor
Freight Emission Factor
kg CO₂e/t·km
wasteToLandfill
Waste to Landfill
t/yr
wasteFactor
Waste Emission Factor
kg CO₂e/kg
annualProduction
Annual Production
t/yr
totalCO2e
Total Footprint
t CO₂e/yr
scope3Total
Scope 3 Total
t CO₂e/yr
scope12Total
Scope 1 + 2 Total
t CO₂e/yr
intensityPerKg
Emission Intensity
kg CO₂e/kg
scope3Proportion
Scope 3 Share of Total
%
fibreProportion
Purchased Fibre Share of Total
%
fibreEmissions
Purchased Fibre Emissions
t CO₂e/yr
How the result is derived
Step by step, from the values you type to the figure on screen.
The 11 inputs are read from the form on every keystroke: Scope 1 — Direct Combustion, Scope 2 — Purchased Electricity, Fibre & Yarn Purchased, Fibre Emission Factor, Chemicals & Dyes Purchased, Chemical Emission Factor, Freight Activity, Freight Emission Factor, Waste to Landfill, Waste Emission Factor and Annual Production.
Each value is checked against the accepted range in the input table below. A value outside its range stops the calculation rather than producing a misleading figure — the results blank out and a message appears.
The validated values are substituted into the expression above, which resolves Total Footprint together with every supporting figure in one pass — no value is carried over from a previous entry.
The supporting outputs — Scope 3 Total, Scope 1 + 2 Total, Emission Intensity, Scope 3 Share of Total, Purchased Fibre Share of Total and Purchased Fibre Emissions — come from the same pass, so they always describe the same case as the headline figure.
Results are rounded for display only. The full-precision value is used throughout the chain, so reading a rounded intermediate figure back into the tool by hand can shift the last digit.
What each input means
Where to read each value on the floor, the unit it must be in, and the range the tool accepts.
Input
Unit
Accepted range
Default
What it means
Scope 1 — Direct Combustion
t CO₂e/yr
0 to 1000000 t CO₂e/yr
4200
Scope 2 — Purchased Electricity
t CO₂e/yr
0 to 1000000 t CO₂e/yr
8600
Fibre & Yarn Purchased
t/yr
0 to 1000000 t/yr
3000
Fibre Emission Factor
kg CO₂e/kg
0 to 60 kg CO₂e/kg
5.5
Chemicals & Dyes Purchased
t/yr
0 to 1000000 t/yr
400
Chemical Emission Factor
kg CO₂e/kg
0 to 60 kg CO₂e/kg
3.2
Freight Activity
t·km/yr
0 to 1000000000 t·km/yr
3500000
Freight Emission Factor
kg CO₂e/t·km
0 to 5 kg CO₂e/t·km
0.08
Waste to Landfill
t/yr
0 to 100000 t/yr
250
Waste Emission Factor
kg CO₂e/kg
0 to 10 kg CO₂e/kg
0.5
Annual Production
t/yr
1 to 1000000 t/yr
3500
What the tool returns
The headline figure and every supporting value it is built from.
Output
Unit
What it tells you
Total Footprint (headline result)
t CO₂e/yr
Scope 1, 2 and 3 combined
Scope 3 Total
t CO₂e/yr
Scope 1 + 2 Total
t CO₂e/yr
Emission Intensity
kg CO₂e/kg
Scope 3 Share of Total
%
Purchased Fibre Share of Total
%
Purchased Fibre Emissions
t CO₂e/yr
Worked example
Given
Scope 1 — Direct Combustion
4200 t CO₂e/yr
Scope 2 — Purchased Electricity
8600 t CO₂e/yr
Fibre & Yarn Purchased
3000 t/yr
Fibre Emission Factor
5.5 kg CO₂e/kg
Chemicals & Dyes Purchased
400 t/yr
Chemical Emission Factor
3.2 kg CO₂e/kg
Freight Activity
3500000 t·km/yr
Freight Emission Factor
0.08 kg CO₂e/t·km
Waste to Landfill
250 t/yr
Waste Emission Factor
0.5 kg CO₂e/kg
Annual Production
3500 t/yr
The tool loads with this case already solved — the Total Footprint shown above is its answer. Change one value and the difference from this baseline is the sensitivity of the result to that variable.
How to use it
Work through the input groups in order — Scope 1 & 2, Scope 3 — Materials and Scope 3 — Logistics & Waste. The defaults are a realistic case, so you can change one value at a time and watch what moves.
There is no calculate button. Every figure recalculates as you type or drag, which is what makes this usable for a what-if sweep rather than a single answer.
Read Total Footprint in the dark results panel — that is the headline figure, expressed in t CO₂e/yr.
Check the supporting rows underneath (Scope 3 Total, Scope 1 + 2 Total, Emission Intensity, Scope 3 Share of Total, Purchased Fibre Share of Total and Purchased Fibre Emissions) before acting on the headline — they are where an implausible input usually shows itself first.
Reset to defaults returns every field to the reference case, which is the quickest way to check whether a surprising result came from the tool or from an input you had changed earlier.
Where this is used
Process planning — establishing Total Footprint before a trial is booked, so machine time and material in Sustainability, ETP & Utilities are committed against a calculated figure rather than an estimate.
Costing and quotation — Total Footprint is an input to the cost sheet, and quoting from a worked number rather than a remembered one is what keeps a margin intact.
Troubleshooting — when the floor result drifts from plan, entering the measured values (starting with Scope 1 — Direct Combustion) shows how much of the gap in Total Footprint each variable explains.
Teaching and study — the accepted ranges bracket normal Sustainability, ETP & Utilities practice, so moving one variable at a time shows the shape of the relationship rather than a single answer.
Assumptions and limits
Emission factors are the whole answer and they vary enormously by fibre, origin and grid — conventional cotton, recycled polyester and virgin nylon are not within a factor of five of each other. Use factors from a recognised database with the vintage recorded, and treat this as a screening model rather than a reportable inventory.
Every input is bounded to the range normal practice occupies (Scope 1 — Direct Combustion 0 to 1000000 t CO₂e/yr, Scope 2 — Purchased Electricity 0 to 1000000 t CO₂e/yr and Fibre & Yarn Purchased 0 to 1000000 t/yr, and so on for the rest). Those bounds are guard rails against typing errors, not a claim that the formula fails one unit outside them.
The calculation is deterministic: the same inputs always give the same result. It carries no allowance for machine condition, operator skill, ambient conditions or lot-to-lot material variation unless an input above explicitly represents one.
Nothing is sent anywhere. The maths runs in your browser, so the numbers you type never leave the page.
Questions people ask
What do I need to know before using the Total CO₂e Footprint Calculator (Scope 1, 2 & 3)?
Have these to hand: Scope 1 — Direct Combustion, Scope 2 — Purchased Electricity, Fibre & Yarn Purchased, Fibre Emission Factor, Chemicals & Dyes Purchased, Chemical Emission Factor, Freight Activity, Freight Emission Factor, Waste to Landfill, Waste Emission Factor and Annual Production. With those entered, the tool returns Total Footprint immediately.
What exactly is Total Footprint?
Scope 1, 2 and 3 combined. It is reported in t CO₂e/yr. It is derived from Scope 1 — Direct Combustion, Scope 2 — Purchased Electricity, Fibre & Yarn Purchased, Fibre Emission Factor, Chemicals & Dyes Purchased, Chemical Emission Factor, Freight Activity, Freight Emission Factor, Waste to Landfill, Waste Emission Factor and Annual Production, and is the figure the rest of the Sustainability, ETP & Utilities calculation is built around.
Which units does this calculator expect?
Enter Scope 1 — Direct Combustion in t CO₂e/yr, Scope 2 — Purchased Electricity in t CO₂e/yr, Fibre & Yarn Purchased in t/yr, Fibre Emission Factor in kg CO₂e/kg, Chemicals & Dyes Purchased in t/yr, Chemical Emission Factor in kg CO₂e/kg, Freight Activity in t·km/yr, Freight Emission Factor in kg CO₂e/t·km, Waste to Landfill in t/yr, Waste Emission Factor in kg CO₂e/kg and Annual Production in t/yr. Mixing unit systems is the most common cause of a result that looks an order of magnitude wrong — convert before typing, not after reading.
What are the other figures under the main result?
They are the intermediate quantities the calculation passes through: Scope 3 Total, Scope 1 + 2 Total, Emission Intensity, Scope 3 Share of Total, Purchased Fibre Share of Total and Purchased Fibre Emissions. They are shown because a headline number nobody can trace is a number nobody trusts — checking them against your own expectation is the fastest way to confirm the inputs were read as you intended.
Can I rely on this for a production decision?
Emission factors are the whole answer and they vary enormously by fibre, origin and grid — conventional cotton, recycled polyester and virgin nylon are not within a factor of five of each other. Use factors from a recognised database with the vintage recorded, and treat this as a screening model rather than a reportable inventory. Treat the output as an engineering estimate that narrows the trial window, not as a substitute for the trial.