Nantong Hongda HD608 is a piece of laboratory equipment used in textile testing and quality control, still in its builder’s current range. Its builder lists test chamber filter diameter 150±0.2 mm, short-arc xenon lamp power 750 W and weight 40 kg. Laboratory equipment covers the instruments and small-scale machines a mill or research laboratory uses away from the production line: colour measurement, sample conditioning and preparation, chemical checks, and laboratory or pilot units for developing a process before it is scaled up.
Laboratory equipmentTesting and laboratoryIn the builder's current range
Key specifications
Specifications incomplete: 2 of 5 key figures recorded
- Samples / beakers per run—
- Max. temperature0–220 °C
- Measuring range200~1000 W/m²
- Accuracy—
- Test standards—
- Test / cycle duration0–99 999 s
- Humidity range65 %
- Lamp power0.75 kW
- Make
Nantong HongdaChinanthongda.com (the builder's website, opens in a new tab) All 8 machines from Nantong Hongda - Class
- Laboratory equipment
- Process stage
- Testing and laboratory
- Lifecycle
- In the builder's current range
- See it
- Exhibited at ITMA ASIA + CITME 2024, Shanghai, stand H8-A14 (as listed by the organiser)
Specification
| Parameter | Value | Comparable | As published |
|---|---|---|---|
| Color touchscreen size | 7 in | ||
| Short-arc xenon lamp power | 750 W | 0.75 kW | Short-arc xenon lamp |
| Short-arc xenon lamp wavelength | 200-1100 nm | Short-arc xenon lamp | |
| Short-arc xenon lamp color temperature | 5500-6000 K | Short-arc xenon lamp | |
| Irradiance at sample stage | 400±10 W/m² | ||
| Irradiance adjustable range | 200~1000 W/m² | ||
| Metal black panel thickness | 0.5±0.1 mm | Metal black panel | |
| Metal black panel size | 150×150 mm | Metal black panel | |
| Metal black panel emissivity | 0.94 | Metal black panel | |
| Infrared heating plate temperature | room temperature ~ 55 ℃ | Infrared heating plate | |
| Infrared heating plate wavelength | 8~14 μm | Infrared heating plate | |
| Test chamber thickness | 10±0.5 mm | Test chamber | |
| Test chamber dimensions | 250×220×100 mm | Test chamber | |
| Test chamber illumination opening size | 100*100 mm | Test chamber | |
| Test chamber filter diameter | 150±0.2 mm | Test chamber filter | |
| Test chamber filter thickness | 0.6±0.1 mm | Test chamber filter | |
| Test chamber filter wavelength | 8~14 μm | Test chamber filter | |
| Irradiance meter test range | 0-2000 W/m² | Irradiance meter | |
| Sample temperature sensor range | 0-220 ℃ | Sample temperature sensor | |
| Sample temperature sensor division value | 0.01 ℃ | Sample temperature sensor | |
| Ambient temperature sensor range | 0-220 ℃ | Ambient temperature sensor | |
| Ambient temperature sensor division value | 0.01 ℃ | Ambient temperature sensor | |
| Temperature rise value range | 0-125 ℃ | ||
| Temperature rise value division | 0.01 ℃ | ||
| Average temperature rise value range | 0-125 ℃ | ||
| Average temperature rise value division | 0.01 ℃ | ||
| Time setting range | 0-99999 min | ||
| Time setting division value | 1 s | ||
| Sampling frequency | 10 times/s | ||
| Test environment temperature | 20±2 ℃ | Test environment | |
| Test environment humidity | 65±4 % | Test environment | |
| External dimensions | W460×D550×H645 mm | ||
| Power supply | AC220V±10% | ||
| Power consumption | 800 W | 0.8 kW | |
| Weight | 40 kg |
Read from the builder's published page: www.nthongda.com, on 2026-10-29.
Check against the machine before you buy or budget on it. Builders publish a range and a configuration; the machine on your floor may be a different variant, may have been rebuilt, and may not carry the options these figures assume. This register records what the builder published, not what any individual machine does.
The record
- Read from
- www.nthongda.com,
- Checked by
- Textile School,
- Last changed